<LOGO>
FM Transmitter Measurement Report
Created: 2024-02-02 06-11-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 29 dBuV R-PCE
Pilot RDS Phase Difference
6.9 kHz 4.8 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
16 kHz 46 kHz 17475 0,0801
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,6 dBr -0,64 dBr -0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 6:10, 2.02.2024
RT
"Zpravy z regionu - rozhovory - dobre rady - souteze "
AF EON
98.6, 101.0, 102.4, 104.7 MHz -
FM Scope Max at: 46 kHz MIN: 16 kHz % above 77 kHz: 0,0801 Acquired: 2024/02/02 6:11:04 Total samples: 17475 Equivalent time: 0:14:33 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600